Current position :
Home > Products > Ion bar

AP-AB1602A Explosion-proof AC Ion Bar

Product Description
Details
Specifications
Installation
Product Description


Details

Specifications
 
Installation
 

Product description    

AP-AB1601A / AP-AB1602A explosion-proof AC voltage static eliminator is a rod type static elimination device developed by Anping Company (AP & T) to eliminate static electricity on the surface of objects.

The product explosion-proof mark is Ex s ⅡB T4 Gb, and the explosion-proof certificate number is GYB16.1549X.

Can be widely used in printing, plastic, textile and other industries with flammable conditions.


Special conditions for product security

The explosion-proof certificate number suffix "X" indicates that the product has special conditions for safe use, as follows:

1. The product should not be used in places where conductive objects may adhere to static electricity electrodes (cannot be used if the static electricity electrodes may adhere to conductive objects such as carbon and metal foil).

2. The static electricity electrode should be installed at least 20mm away from the static electricity removal object.

3 The distance between the static elimination electrode and the mechanical frame should be more than 10mm.

4 Keep the anti-static electrode clean. It is strictly forbidden to dry-clean the electrode holder.

5. The power supply unit does not have an explosion-proof structure and must be installed in a non-hazardous place.

6. The length of the high-voltage cable is up to 8m.

7. Never open the cover.

8. It is forbidden to rub the surface of the product shell to prevent the danger of ignition due to static electricity.


Product Usage Notes

Product allowed environment:

Temperature: (0  + 50) ℃, relative humidity: 35%  75%, altitude: no more than 1000m.

The product is provided with a ground terminal, and the user should be reliably grounded during installation and use.

When the product is used and maintained on site, the principle of "Do not open with power on" must be observed.

The user shall not replace the parts or components of the product by himself, and shall work with the product manufacturer to resolve the faults during operation to prevent damage.

The electrical parameters of the eliminator are as follows:

 

6. The installation, use and maintenance of the product shall comply with the requirements of the product manual and the following relevant standards and specifications:

 GB 3836.13–2013 Explosive environment Part 13: Repair, overhaul, repair and modification of equipment

 GB 3836.15–2000 Electrical equipment for explosive gas environments-Part 15: Electrical installation in hazardous locations (except coal mines)

 GB 3836.16–2006 Electrical equipment for explosive gas atmospheres Part 16: Inspection and maintenance of electrical installations (except coal mines)

  GB 50257–2014 Code for construction and acceptance of electrical installations in explosion and fire hazardous environments

  GB 3836.18–2010 Explosive atmospheres Part 18: Intrinsically safe systems

Please read the instruction manual carefully before installing and using this equipment.

The entire set of equipment must be reliably grounded during use, and the grounding resistance is less than 4 ohms; otherwise, the ion rod may be abnormal or even damaged.

It is not suitable to use this equipment in the environment of> 70% humidity.

It is strictly forbidden to disassemble the product without authorization, and internal maintenance and repair must be performed by professionals.

It is strictly forbidden to touch the product with water stains, otherwise abnormalities may occur, resulting in electric shock or fire.

When inspecting or replacing the product, please turn off the power, otherwise it may cause electric shock or fire.

The product is designed to eliminate static electricity, and other uses are strictly prohibited. Any abnormal use may cause hidden dangers such as machine failure, electric shock, and fire.

It is strictly forbidden to touch the electrode needle while the power is on, otherwise it may cause malfunction and electric shock accident.

15. The discharge needle is a sharp metal object, please use it with care.

16. Before powering on the product, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage to the product or even failure.

17. Please check the power cord of the product regularly. If it is damaged, please replace it immediately, otherwise it may cause leakage and abnormal working.

 

Products features and working principles

(1) Structural characteristics:

1. It is a rod-type, horizontal active static eliminator.

2. The stick is small and exquisite.

3. Work under high voltage and micro current (μA level).

4, with anti-shock function, to avoid accidental human body contact and cause injury.

5. It has a certain anti-flammability function, which can be applied to places with flammable and explosive conditions corresponding to Ex s B T4 Gb or lower.

6. Special bar notch on the back of the body, the mounting bolt can be moved.


(2) working principle:

AP-AB1601 / AP-AB1602 explosion-proof AC voltage static eliminator uses high-frequency AC high-voltage, and acts on a dedicated transmitting electrode through an impedance coupling device to ionize air molecules and generate positive and negative high-voltage ions; and transport them to the static elimination The surface of the object neutralizes the positive and negative electrostatic charges to achieve the purpose of efficient and reliable elimination of static electricity.

 

Specifications

Model

AP-AB1601A

AP-AB1602A

Explosion-proof sign

Ex s ⅡB T4 Gb

Ex s ⅡB T4 Gb

Explosion-proof certificate No.

GYB16.1549X

GYB16.1549X

Working Voltage

Power frequency AC4000V

Power frequency AC4000V

Power

20W

20W

Ion emission

Power frequency AC

Power frequency AC

Transmitting electrode

SUS

SUS

Discharge structure

Resistance coupling

Resistance coupling

Electrode high voltage

≤4000V

≤4000V

Electrode needle combined capacitor

3.5pF

3.5pF

Discharge range

L*W*H110mm→3000mm

*300mm*100mm

L*W*H110mm→3000mm*300mm*600mm

Installation distance

30100mm

100600mm

Air pressure

——

≤0.6MPa

Compressed air connector

——

Φ8-G1/8 Red

Ion balance

≤|±300V|

≤|±300V|

Discharging speed

≤2.5S  (Different test conditions will result in different test data)

≤2.5S  (Different test conditions will result in different test data)

Working temperature

0°C – 50°C

0°C – 50°C

Working humidity

70%

70%

Bar material

Flame retardant PVCAL

Flame retardant PVCAL

Dimensions

L*W*H110mm→3000mm

*20.4mm*32mm

L*W*H110mm→3000mm*28.6mm*38.7mm

Installation accessories

Hex Bolts M4*20

Hex Bolts M5*20

Power supply

AP-AY1603/2603

AP-AY1603/2603

Power cord

2.5m (Can be customized according to requirements, the maximum length is 8m)

2.5m (Can be customized according to requirements, the maximum length is 8m)

Warranty

1 year

1 year

Certification

CE

CE


Tks For Your Appreciation!

Welcome To Inquiry Us For The Quotation Of Such Product And Company Profile To Find The Most Competitive

Inquiry
If you would like to contact us for more information about our products, please fill out the form below, thank you.
Your name (required):
Your E-mail (required):
Country:
Your phone number:
Your message: