Current position :
Home > Products > Ion bar

AP-AB1103 AC ELECTROSHOCK-PROOF ION BAR

General
Industry Application
Product Feature
Specification
Working Ways (AC)
Use and Installation
General
AP-AB1103 ionizing bar is the bar shape static eliminator developed by Shanghai Anping Static Technology Co.,Ltd.

AP - AB1103 ionizing bar generates positive and negative ion on emitter by AC high voltage and transfer the ion by pressed air to the object surface to be static removed. Thus neutralize the ion on the object surface and eliminate static efficiently and reliably.

It is widely used in electronics, plastics, chemicals, printing, textile, optical and other industries.
Industry Application
Can be used in electronics, plastics, chemicals, printing, textile, optical and other industries.

Product Feature
(1)Bar shaped and cross over static eliminator
(2)Compact structure and elegant appearance
(3)Working under high voltage and micro current (μA level)
(4)Electroshock-proof function
(5)Stripe shaped notch on the back of the bar for user to fasten the bar

Safety warning   

Read this manual carefully before installing and using the device.

Be sure the device connect to ground reliably

Do not use this device in the environment where the humidity> 70%.

It is strictly prohibited to use this equipment in combustible and explosive environment.

Internal maintenance and repair must be carried out by professionals

 Installation guide  

(1)Choose an optimal position and fix the ion bar and power supply tightly.

(2)Insert the HV plug on the bar body into the HV output connection on power supply.

(3)Connect the ground end on the bar body to the ground bolt on the power (4)Switch on the power

Specification

Model  

AP-AB1103/ AP-AB1108

Input voltage

AC220V/50Hz or  AC110V/60Hz

Working voltage

Power frequency AC7000V

Power  

20W

Ion emission

Power frequency communication

Transmitting electrode

SUS

Discharge structure

Resistance coupling

Discharge range

L*W*H

150mm→3000mm*300mm*100mm/

150mm→3000mm*300mm*600mm

Installation distance

30→100mm/100→600mm

Ion balance

≤|±100V|

Air pressure

NO /≤0.6MPa

Throttle valve

Air source connector

NO /Φ8-G1/8 Black

Discharge time   

≤1.0SWorking distance 100mm/

≤2.5SWorking distance 300mmAir pressure 0.3MPa

Working temperature  

0°C - 50°C

Working humidity

70%

Bar material

Flame retardant PVCAL/Flame retardant PVCSUS

Bar length

150mm→3000mm

Mounting accessories

M4×20 Hexagon mounting bolt/

M5×20 Hexagon mounting bolt

Supporting power supply

AP-AY1502/ AP-AY2502

High voltage cable length

2.5mCan be customized according to requirements,line length≤12m

Warranty period

1Year

Certificate

CE

Industry application

Film, printing, plastic, textile, etc.

Working Ways (AC)




Elimination Effect



Testing instrument :3M-711 Static tester
Testing standard:ESD.STM3.1-2000;SJ/T 11446—2013
Testing voltage :±1000 — ±100V Attenuation
Testing environment :Humidity50±5% Temperature:23±3℃
Testing data as below(Test distance:100mm,Ion bar width:410mm):






Test standard:ANSI/ESD.STM3.1,ANSI/ESD.SP3.3,SJ/T 11446—2013
Test Device:Trek157 static detector
Test Voltage:±1000V → ±100V attenuation
Test environment:Humidity 50±5%;Temperature23±3℃
Use and Installation
1.Installation guide

(1)Choose an optimal position and fix the ion bar and power supply tightly.
(2)Insert the HV plug on the bar body into the HV output connection on power supply.
(3)Connect the ground end on the bar body to the ground bolt on the power.
(4)Switch on the power.

2.Outline dimensional drawing


3.Positioning

Maintenance   

User should clean and maintain timely to ensure the good performance of the ion bar according to working environment and requirement of ESD protection. Clean the carbon materials on election bare tip, discharge pad and metal discharge body with static brusher or clean cloth with ethanol can obviously improve the performance.

Caution

Must be done after the power is shut done for 10 minutes

Restart must wait till alcohol completely volatilized after cleaning by clean cloth with ethanol. Any other organic solution is not allowed to be used to clean the ion bar.

Stop using the device when red indicator turns off on power supply. Re-use the device only after checking and repairing by professionals.

 

 After Sales Service   

(1)AP-AB1103 ion bar is strictly inspected before ex-work and match the entire related technical standard indicated in this manual.

(2)GuaranteeRepair or change any damaged parts caused by quality reasons free of charge within one year from the date of purchase after we confirm the quality issue.

(3)Above guarantee is not fit for the following situationAlternation of the device, wrongly used, incorrect installation, abuse, negligence, and accidental damage, wrong input voltage, unpacking and repacking by user itself or maintain by other unauthorized service department.

(4)AP&T is free from any related responsibility of using the product except the parts specified here above.


Inquiry
If you would like to contact us for more information about our products, please fill out the form below, thank you.
Your name (required):
Your E-mail (required):
Country:
Your phone number:
Your message: